Product Center
Pipe Burst Testing Bench
Keywords:
Category:
Product Description
Scope of application:
Aluminum flat tubes for automotive radiators, oil coolers, heaters, condensers, evaporators, and more.
Main technical parameters:
◎ Pressure range: 0–21 MPa (oil cooler)
◎ Test station: 1 station
◎ Measurement accuracy: Pressure measurement accuracy: ≤ ±0.01 MPa
◎ Test medium: Hydraulic oil;
◎ Ambient temperature: Room temperature;
◎ Test tube length range: 450–600 mm;
◎ Test tube width range: 16–80 mm;
◎ Control modes: Manual control / PLC control / Computer control
◎ Power supply: 380V, 50Hz, 15kW
◎External dimensions: 1800*1000*1700
◎ Equipment weight: 1200 kg
Related products
Get a quote
CONTACT US
Factory Address: No. 26, Shameng Road, YuHong District, Shenyang City
Office Address: No. 1 Qishan Middle Road, Huanggu District, Shenyang City (13th Floor, Northeast Machinery Building)
Postal code: 110032
Phone:024-86222398 86244992 82059405
Mobile phone:13909839892
Fax:024-86244992
Email:huizhiii@163.com